Contents
The Financial Times reported on 8 November 2026 that Anthropic had agreed to pay $3.4bn for 1.7 GW of gas-fired generators [1]. Our bet at Junyr is that a large share of office work never needs power on that scale: it can run in-house on a small open model, inside a solid harness, on a few hundred watts.
Even Anthropic tells its customers to route by task. Releasing Fable 5.2 the next day, it advised them to start most work on Opus 5.5 and to keep Fable for harder tasks [2]. Two things keep our position a bet: we have not measured that share, and we do not claim parity with Sonnet 5.5, which scores 55 against 32 for the best open weights released by 27 October on an independent index [3].
This article sets out the bet, the evidence for it, the evidence against it, and the measurements that would settle it.
- The order: a press report. Anthropic announced nothing, the equipment is generators and the site is unknown.
- The gap: 55 against 32 on the Artificial Analysis index of 27 October 2026, 20 for Qwen3.8 27B (the model we run in a 4-bit version) on its live ranking of 10 November, and no benchmark that tests a small open model against Sonnet 5.5 inside the same harness on office tasks.
- Our field figure: Qwen3.8-27B at 8 bits, split across two Apple Mac Studio machines, about 21 tokens a second in generation, measured on 30 October 2026 [4]. We publish no measurement for the 4-bit version that runs on a single machine.
- Still declared, not measured: “under 100 W”. Our hardware price (about €2,000 excluding VAT for one refurbished Mac Studio) and our 100% photovoltaic, off-grid supply are our own statements. The next step is a wall meter.
What did the FT report about Anthropic’s gas order?
According to the FT, as relayed by The Next Web, Anthropic signed in late September with OnePWR Solutions, a San Antonio firm, to take over its orders for 1.7 GW of large Caterpillar generators, plus the work needed to install the machines [1].
- Status: a press report citing one person who knows about the deal. Both companies declined to comment, The Next Web has not confirmed it independently, and Anthropic announced nothing.
- Equipment: large gas-fired generators. The reports do not speak of turbines.
- Structure: Anthropic did not buy OnePWR itself and none of its staff moved to Anthropic, according to the FT. Where the generators will be used is not known.
The energy argument holds at the level of the system, where demand is counted in gigawatts and in percentages of national consumption; we found no per-query figure recent enough to cite, so we say nothing about the energy of a single answer.
- An equipment maker: GE Vernova’s gas power equipment backlog and slot reservation agreements grew from 116 to 122 GW in the third quarter of 2026, and the company targets at least 130 GW by the end of the year [5].
- United States: data centres use about 4.5% of the country’s electricity and could reach 11.8% by 2030 (range 9.5 to 15%), according to Lawrence Berkeley National Laboratory as reported by E&E News on 22 June 2026 [6].
- One operator: Google’s electricity use rose 37% in 2025, its largest one-year increase, according to its 2026 environmental report as summarised by Let’s Data Science [7].
The frontier is now an energy buyer.
Anthropic itself keeps its top model for the hardest work
Anthropic’s release note of 9 November tells users to “start with Claude Opus 5.5, our strongest daily driver” for most coding and knowledge tasks, to switch to Fable or Mythos for more complex work, and to use Sonnet 5.5 or Haiku 5.5 for simpler work [2]. Routing by task is the vendor’s own advice.
- Price per million output tokens: Fable 5.2 $40, Opus 5.5 $20, Sonnet 5.5 $10. Input tokens cost $8, $4 and $2 [2] [8].
- Capability on one independent index (see Figure 1): Opus 5.5 58, GPT-6 Astra 57, Sonnet 5.5 and GPT-6.1 Sol 55, and 32 for the best released open weights, DeepSeek V4.1 Flash and GLM-5.3 [3] [9]. Kimi K3.1 Pro reached 46, but its weights had not been released on 27 October.
- What the index measures: a composite of general evaluations run by a third party at maximum effort. It says nothing about a given company’s tasks inside its own harness.
Can a small open model match Sonnet 5.5?
On broad intelligence, not yet; on one narrow task, it can. Our article of 10 October cited a benchmark in which a security-document classifier, fine-tuned from an open 27-billion-parameter model, reached 95.0% accuracy against 75.4% to 79.9% for the commercial models tested under the same protocol [10]. That result sits comfortably beside Figure 1: one measures breadth, the other depth.
- The index measures breadth: many hard, varied tasks. Sonnet 5.5 scores 55 and the best released open weights 32 (27 October). On 10 November the live ranking page showed 33 for DeepSeek V4.1 Flash, listed Kimi K3.1 Pro (46) among the models whose weights can be downloaded, and gave 20 to Qwen3.8 27B at Xhigh effort [11]. We run a 4-bit version of that model, which the page does not score.
- The classifier measures depth: one narrow, repetitive task with seven fixed categories, after fine-tuning, where the specialist wins.
- Office work is a mix. Our hypothesis is that much of it (sorting, extracting, filling in, drafting from a known pattern) looks like the second case. We have not counted it.
The evidence against our bet deserves as much room as the evidence for it, and some of it comes from our own pages.
- Our harness article of 4 November lists, among the things we do not know, which AI model implements best in our framework: the model is not recorded per run [12].
- The LinkedIn post we published on 10 November 2026 said that our local model’s results were “equivalent to Sonnet 5.5”. No published benchmark places a small open model and Sonnet 5.5 inside the same harness on office tasks, so that sentence has no support today. We correct it here.
- Cheaper inference tends to raise total use. That is the Jevons paradox, which we discussed in our article on the price war [13]. A frugal machine does not guarantee a frugal company.
Breadth and depth are different tests.
Field element: what runs on our own machines today
These are our own statements and measurements, taken on one site. The model most used on our sovereign agentic platform is Qwen3.8-27B, an open model quantised to 4 bits, which runs on a single Apple Mac Studio M4 Max with 36 GB: that is our statement, and we have published no measurement for this set-up. What we did measure, on 30 October 2026, is the same model at 8 bits, split across two such machines: about 21 tokens a second in generation [4].
- Speed on that set-up: about 325 tokens a second to read a prompt, 3.3 seconds for a short chat, and 8.2 seconds of reading before the first word on a prompt of 2,651 tokens.
- Layout of that set-up: 14.75 GB of weights sit on each machine, and the two halves of the model talk over a Thunderbolt 5 cable.
- Scope: our internal note rates the service fit for light, text-only internal use. The measurement reaches no further than that.
The harness, the software that frames the model, is designed to decide which tier answers a request: a small specialised local model still to come, the local 27B, or a cloud model by API, with a human checking the output before use (see Figure 2). We described what a harness does in an earlier article [14].
- Documented: the three tiers, as a design in our internal notes; tier 1 is planned, not yet in service [4].
- Not documented: the share of requests each tier serves. The harness keeps no counter per tier yet.
- Consequence: our LinkedIn post called the open model the most used on the platform. The configuration makes that plausible. Nothing we have logged proves it.
Declared, measured, unknown: the table we will keep updated
In the LinkedIn post we published on 10 November 2026, we gave two figures for the inference machine: under 100 W and under €2,500. The price holds: the model most used runs on one refurbished Mac Studio M4 Max with 36 GB, bought at about €2,000 excluding VAT. That is our own statement, and this article publishes no invoice. The power figure is still a declaration that no wall meter has confirmed. The post gave no speed; the only one we have measured comes from a different set-up, the 8-bit version across two machines.
| Claim | Status on 10 November 2026 | What would settle it |
|---|---|---|
| Qwen3.8-27B at 8 bits, split across two machines, runs at about 21 tokens a second | Measured, 30 October 2026 | The same measure on the 4-bit, single-machine set-up, with real production prompts |
| The inference machine draws under 100 W | Declared by us, not measured | A wall meter on the machine over a working week |
| The hardware costs under €2,500 | Our statement: one refurbished Mac Studio M4 Max 36 GB at about €2,000 excluding VAT; no invoice published here | The invoice |
| The datacentre is 100% photovoltaic and off-grid, with no grid fallback | Our statement, confirmed on 10 November 2026; no meter reading published here | A published energy log: panel output, battery state and load |
| Results equivalent to Sonnet 5.5 on office tasks | Hypothesis, withdrawn as a claim | The same tasks in the same harness, both models, scored blind |
| Share of requests served locally | Unknown | A counter per tier in the harness |
One detail shows how far we are from a full measure. Our only consumption figure for the site, an estimate of about 1.1 kWh a day that includes a margin, covers a Mac mini, a screen, a dock and the routers. The Mac Studio machines are not in it yet.
Taking 100 W as an illustrative target, the arithmetic is short: a machine drawing 100 W all year uses 876 kWh, and the rest follows from public data [15] [16].
- Panels: with PVGIS, an annual balance needs about 0.78 kWp in Paris (1,129.52 kWh per kWp a year) and 0.54 kWp in Marseille (1,624.29). A Paris December yields 41.63 kWh per kWp, so covering that month’s 74.4 kWh takes about 1.8 kWp. Nights need a battery, which we have not sized.
- Carbon: at ADEME’s 2026 figures of 420 g CO2e per kWh for gas and 20 to 30 g for new solar panels, 876 kWh emits about 368 kg a year on gas and 17.5 to 26.3 kg on panels (see Figure 3). The panel figure excludes the machine, the battery and the inverter.
- Hardware: at about €2,000 excluding VAT for one refurbished machine, it amortises at about €56 a month over 36 months, before electricity.
The same arithmetic yields a striking ratio that needs a warning: 1.7 GW divided by 100 W gives 17 million machines of the kind we describe. The two figures are of different kinds, since 1.7 GW is the rated capacity of the generators and 100 W a continuous draw, and the hours those generators will run each year have not been reported.
- What the ratio shows: the size of the order.
- What it hides: the fuel actually burnt, which depends on running hours and load.
- How we use it: once, as an order of magnitude.
Rated capacity is a ceiling.
What should an SME check before buying an AI machine?
For the head of an SME or a mid-sized company, deciding where AI runs is a sizing exercise on your own tasks, and the order of the steps settles most of the cost, because a machine bought before the tasks are counted is sized on a guess.
- Euros: in the cloud, list prices run from $10 per million output tokens for Sonnet 5.5 to $40 for Fable 5.2 [8] [2]. In-house, the hardware (in our case one refurbished machine at about €2,000 excluding VAT, our own figure) amortises over about three years, plus electricity, plus the hours of whoever maintains it.
- Weeks: a local model needs a harness, a test set built from your own requests and a few weeks of logging before you know what share it can carry. That delay is our recommendation; we have not measured it.
- Risks: one machine is one point of failure. Confidentiality improves, since documents stay on your premises. Quality falls on the hardest tasks, which is why a cloud route stays open.
- Decision: route by task first, then buy capacity for the share that passed.
The three steps below can be lifted as they stand; they are our recommendation, in this order.
- Count. Log a month of real requests and sort them into routine, structured and hard.
- Test. Run the same requests through a local open model and a cloud model inside the same harness, scored blind by the people who do the work.
- Size. Buy local capacity for the share that passed, keep a cloud route for the rest, and meter both, in watts and in euros.
Two conditions make the local share larger. We draw them from our own practice, without a measurement behind them: users trained to write precise requests and to check what comes back, and a harness tuned to the tasks, with rules, context and checks set by people who know the work.
Gas or sun is decided one task at a time
That post ended on “gas or solar, your choice”, and the substance behind that line is narrower and more useful: each task your company hands to AI can be served by the largest model available or by the smallest one that passes your own test, and the second is the one that can run on a few panels on your roof.
- Our commitment stays the same: frugal AI that serves people and keeps their documents confidential, with the frontier models as a route for the hard tail.
- Our next measurements, in this order: a wall meter on the inference machine, a counter per tier in the harness, and a blind comparison with Sonnet 5.5 on a set of our own office tasks.
- Our promise: we will publish those results here, including the ones that weaken the bet.
The meter goes on first.
This article mixes four kinds of evidence, and each figure carries its label. Third-party reports: the generator order (FT via The Next Web, one source, confirmed by neither company), GE Vernova’s gas power equipment backlog, the Lawrence Berkeley and Google figures, all read through secondary coverage where stated. Company statements: Anthropic’s prices and recommendation. Our measurements: the speed of the 8-bit, two-machine set-up on 30 October 2026, on short prompts, on one site. Illustrative arithmetic: everything derived from a 100 W load, a target that no meter has confirmed. The power figure (“under 100 W”) is our own declaration and has not been measured; the hardware price (about €2,000 excluding VAT) and the off-grid solar supply are our own statements, with no invoice or meter reading published here. No client data is used.
Sources
- The Next Web, ‘Anthropic buys $3.4bn of gas generators for its data centres, FT reports’, reporting the Financial Times, 8 November 2026. We did not read the FT article itself.
- Anthropic, ‘Introducing Claude Fable 5.2 and Claude Mythos 5.2’, release note, 9 November 2026.
- Artificial Analysis, ‘Artificial Analysis Intelligence Index v5’, 27 October 2026.
- Junyr, serving note for the local model and architecture notes, measurements of 30 October 2026, internal documents, not public.
- GE Vernova, ‘GE Vernova reports strong third quarter 2026 financial performance, raises 2026 guidance and increases share repurchase authorization’, press release, 28 October 2026.
- E&E News, ‘US data centers’ electricity use could double by 2030, DOE lab says’, reporting Lawrence Berkeley National Laboratory, 22 June 2026.
- Let’s Data Science, ‘Google Reports 37% Rise in Electricity Use Driven by AI Buildout’, reporting Google’s 2026 environmental report, 2 July 2026.
- Anthropic, ‘Pricing’, documentation page, consulted 10 November 2026.
- Artificial Analysis, ‘Claude Sonnet 5.5’, model page, Intelligence Index v5.0.1, consulted 10 November 2026.
- Junyr, Why agentic projects don’t (yet) have a positive ROI, blog article, 10 October 2026.
- Artificial Analysis, ‘Open source models’, ranking page, Intelligence Index v5.0.1, consulted 10 November 2026.
- Junyr, We measure what our AI harness sees, not what it prevents, blog article, 4 November 2026.
- Junyr, The price war has begun, blog article, 27 September 2026.
- Junyr, Harness engineering: the software layer that turns a model into an agent, blog article, 20 September 2026.
- European Commission, Joint Research Centre, PVGIS 5.3, PVcalc, Paris and Marseille, fixed 35 degree mounting, 14% losses, SARAH3 database, queried 10 November 2026.
- Connaissance des énergies, ‘L’empreinte carbone du photovoltaïque en France serait très inférieure à celle actuellement retenue’, reporting ADEME’s release of 1 September 2026, September 2026.
Frequently asked questions
Did Anthropic buy gas turbines?
The available reports describe generators and no announcement. The Financial Times reported on 8 November 2026, as relayed by The Next Web, that Anthropic agreed to pay $3.4bn for 1.7 GW of gas-fired generators made by Caterpillar, by taking over orders placed by OnePWR Solutions.
- The equipment is described as large generators; the reports do not mention turbines.
- The report cites one person who knows about the deal, and both companies declined to comment.
- Where the generators will be used is not known.
Can a small open model replace Claude Sonnet 5.5 for office work?
It has not been shown. On the Artificial Analysis Intelligence Index v5 of 27 October 2026, Sonnet 5.5 scores 55 and the best released open-weight models score 32. A small open model can win on a narrow task, which is why Junyr treats office work as a hypothesis to test task by task.
- No published benchmark pairs a small open model with Sonnet 5.5 inside the same harness on office tasks.
- A fine-tuned 27-billion-parameter open model reached 95.0% on one narrow classification task, against 75.4% to 79.9% for the commercial models tested.
- Qwen3.8 27B, the model we run in a 4-bit version, scores 20 on the Artificial Analysis ranking page (Xhigh effort, consulted 10 November 2026); our 4-bit build itself has not been scored.
- Anthropic itself recommends Sonnet 5.5 or Haiku 5.5 for simpler work and Fable or Mythos for more complex work.
How much solar power does a 100 W AI machine need?
As illustrative arithmetic, 100 W running all year uses 876 kWh. With PVGIS data, an annual balance needs about 0.78 kWp of panels in Paris and 0.54 kWp in Marseille, and about 1.8 kWp to cover a Paris December, plus a battery for the nights.
- PVGIS gives 1,129.52 kWh per kWp a year in Paris and 1,624.29 in Marseille (fixed 35 degree panels, 14% losses).
- On ADEME's 2026 figures, 876 kWh emits about 368 kg CO2e on gas and 17.5 to 26.3 kg on new solar panels.
- The battery is not sized here, and the panel figure excludes the machine, the battery and the inverter.
What should an SME measure before running AI on its own machines?
Three things, in order: which share of its real requests is routine, how a local model and a cloud model compare on those requests inside the same harness, and how many watts and euros the local machine actually uses.
- Log real requests and sort them into routine, structured and hard.
- Have both models scored blind by the people who do the work.
- Put a wall meter on the machine and keep a cloud route for the hard tail.
What is model routing, and how does it apply to office AI?
Model routing sends each request to the smallest model that can handle it and escalates only when needed. Our design has three tiers, a small local model (planned), a local 27-billion-parameter model and a cloud frontier model, with a harness choosing between them; no share of traffic per tier has been measured.
- Anthropic itself advises Opus 5.5 for everyday work and Fable 5.2 for the hardest tasks.
- Tier 1, a small specialised local model, is planned and not yet in service.
- We keep no counter per tier yet, so we cannot say how much traffic stays local.
Is running AI locally cheaper than paying per token?
We cannot say yet. One refurbished Mac Studio M4 Max costs us about €2,000 excluding VAT, about €56 a month over 36 months before electricity, while cloud list prices run from $10 to $40 per million output tokens; without our token volume and a wall-meter reading, no price per token is publishable.
- Sonnet 5.5 costs $10 and Fable 5.2 $40 per million output tokens (Anthropic, November 2026).
- The hardware price and the 100 W figure are our own declarations, with no invoice or meter reading published.
- A local machine only pays off for the share of requests it can carry, which is why the method starts by counting requests.